Concrete engineering performance and construction economic benefits are both affected by the metering accuracy of the wet batch concrete plant and engineering performance of concrete can be guaranteed after the metering accuracy is improved. There are several methods which can improve the metering accuracy in terms of concrete batching plant.\

wet batch concrete plant.jpg

1. Reduce the material discharge opening. According to the structural features of the the batching machine, two pieces of angle steel can be added. The function of this device is to reduce the opening diameter. From the actual application effect, the phenomenon of exceeding discharging of aggregate has been effectively controlled.

2. Improve the accuracy of the control system. The control system chosen by Haomei Machinery can control the error In addition, it is necessary to match the main and auxiliary door switching mode and jog batching mode. The application of this mode can improve the synergy of the feeding of the two doors. After reaching a certain number, the auxiliary door will be closed in time, and then the main door will participate in the batching process to complete the batching operation of the remaining part of the aggregate.

3. Strengthen maintenance. With the prolongation of use time, the stability and accuracy of related devices such as sensors will be greatly reduced. In this regard, the inspection and maintenance of the instrument must be done in daily use, and the parts should be repaired. Lubricate the cylinder regularly, and add 2 small cylinders if necessary, so as to adjust the air pressure reasonably.

4. Add a gas-water separator. According to the structural characteristics of the trachea, an air-water separator is arranged in it, and the device is used to filter out the moisture in the air, so as to ensure the smooth operation of the pipeline.

5. Install the mother-child screw. According to the structural characteristics of the large powder conveying screw, the small screw can be set at the end of the device, and the two types of devices work together. If there is 20kg of powder in the large screw, the operation will be suspended immediately, and then the powder will be transferred to the corresponding weighing scale; the small screw can achieve the effect of accurate measurement and help reduce errors.

6. Replace the solenoid valve. Since the aggregate silo is prone to exceed the standard, it is necessary to accurately analyze the working state of the cylinder solenoid valve, and replace it with a new one if it lacks sufficient sensitivity. In addition, a limit rod can be added to to reduce the weighing error.

There are also other measures Haomei Machinery has taken to ensure high metering accuracy of our concrete batching plant. Welcome to inquire concrete mixer plant price.

Original source: https://www.concretebatchplanthm.com/a/how-to-improve-metering-accuracy-of-wet-batch-concrete-plant.html

Tags: wet batch concrete plant

Prev: How Does Different Types of Concrete Plant Silos Work

Next: Different Types of Self Loading Concrete Mixer Truck

CONTACT
1
Want to get quotation of concrete batching plant at once? Contact Us. Quick reply is as efficient as our equipment.
+86-15978414719